Optimal prescription isodose line in SBRT for lung tumor treatment with volumetric-modulated arc therapy
David Wang, Albert Denittis, Tracey Evans and Thomas Meyer
It is crucial to spare lung when treating early stage lung carcinoma with stereotactic body radiotherapy (SBRT) for minimizing the radiation induced toxicities, such as radiation pneumonitis and late fibrosis. A retrospective study was performed with a combination of approaches to determine the optimal range of prescription isodose line (P-IDL) within which lung tissue was best spared in SBRT plans with Volumetric-Modulated Arc Therapy (VMAT) and Monte-Carlo-like dose calculation algorithm.
Twenty clinically-delivered SBRT lung plans were optimized using traditional LINAC MLC based approaches: an average P-IDL of (88.8 ± 0.5)% (the error bar of all the data is the 95% confidence interval (CI)). The plans were then re-optimized using a new combination of approaches with variation of P-IDL from 60% to 90% for each case. The combination of approaches included finding and utilizing an optimal P-IDL, implementing tuning ring structures internal and external to the target, as well as normal tissue objective and equivalent. The plans were evaluated with the following indexes: 1. R50%, the ratio of 50% prescription isodose volume to the plan target volume (PTV); 2. V20 and V5, the volume of lung within 20Gy and 5Gy, respectively; 3. PCI, the Paddick comformity index; 4. D2cm, the maximum dose at 2 cm from PTV in any direction; 5. MLD, the mean dose in total lung volume; 6. Focal Index (FI), an indicator of dose in the core of the target.
The optimal P-IDL was found to be in the range of 75-80%. The average optimal P-IDL for the 20 cases was (77.9 ± 0.9)%. With the optimization strategies the average PCI was increased by (10.3 ± 2.1)%; the average R50%, V20, V5, D2cm and MLD were decreased by (29.1 ± 4.1)%, (26.9 ± 5.4)%, (13.9 ± 3.5)%, (13.4 ± 4.3)% and (16.7 ± 2.3)%, respectively. The FI was increased by (23.7 ± 1.3)%.
The optimal P-IDL range was 75-80% for SBRT VMAT lung treatment plans. The application of the set of optimization approaches can significantly improve the lung sparing in SBRT VMAT plans with AXB dose calculation algorithm and makes treatment plans more conformal in high, intermediate and low dose regions, while higher dose is delivered to the target.
Keywords: optimal P-IDL, lung SBRT, AXB, VMAT, lung sparing
Full Text (IP)
Purchase Article (PDF)